How To USE
What does your substance look like?
Powder = ready to scoop
Pill = crush the pill and add the contents to a separate container and shake it well.
Ready to Scoop = Flour or table salt consistency
Crush More = sea salt consistency
Once you have a flour or table salt consistency you’re good to go. Otherwise, crush more.
Grab the water pouch, tear the top, and lightly compress the edges to hold it open.
Measure a level scoop of the substance into the mini spoon. Warning: Using too much or too little product will not yield accurate results.
Add 1 scoop to the water pouch. Use mini spoon to stir well for 15 seconds.
Hold the water pouch open and upright.
Do NOT let it go until testing is over.
Dip the strip into the water pouch, up to the red arrows, for 15 seconds.
Do NOT let go of the strip.
Do NOT dip the strip past the water limit.
Place the strip on a dry and flat surface. Result window facing up. Wait 3 minutes.
Important: Do NOT read the test results before 3 minutes or after 10 minutes or results will not be accurate.
After waiting 3 minutes, read the results:
One Red Line on Top:
POSITIVE.
Fentanyl detected.
Two Red Lines:
NEGATIVE.
Fentanyl not detected.
- If you see a second line after three minutes, no matter how faint, it is still a negative result.
No Red Lines or One Red Line on the Bottom:
INVALID.
- Restart test from the beginning.
After 10 minutes the test strip is invalid and should be discarded.
WARNING: OVERDRIVE FENTANYL TEST STRIPS ARE USED TO TEST SUBSTANCES FOR THE PRESENCE OF FENTANYL AT A CONCENTRATION OVER 15 ng/ml IN WATER. THEY ARE NOT INTENDED TO DETERMINE THE COMPOSITION, PURITY OR SAFETY OF ANY SUBSTANCE. THEY ARE NOT INTENDED TO DETECT ANY OTHER OPIOIDS. THIS TEST IS INTENDED FOR HARM REDUCTION PURPOSES. IT DOES NOT ENCOURAGE THE USE, SUPPLY OR PRODUCTION OF UNLAWFUL SUBSTANCES. DO NOT USE AFTER EXPIRATION DATE. TEST STRIPS MUST REMAIN IN POUCH UNTIL USE. EACH TEST STRIP IS INTENDED FOR SINGLE USE ONLY AND SHOULD BE DISCARDED AFTER USE. NOT FOR IN VITRO DIAGNOSTIC USE. STORE AT 4˚C TO 30˚C (39˚F TO 86˚F) SEALED. KEEP AWAY FROM DIRECT SUNLIGHT. FAILURE TO FOLLOW THE USER INSTRUCTIONS MAY RESULT IN AN INACCURATE TEST RESULT.
00:00:12:23 - 00:00:15:20
The point is to get a flour salt consistency.
00:00:15:20 - 00:00:19:11
Now the first step is you want to take out your tools
00:00:19:13 - 00:00:21:22
from your kit and open this up.
00:00:21:22 - 00:00:24:22
Inside, you're going to find two essentials.
00:00:24:23 - 00:00:27:22
You're going to find your testing strip in your spoon,
00:00:27:22 - 00:00:29:13
which is where we're going to test everything out.
00:00:29:13 - 00:00:31:07
Now, this is where the real party starts.
00:00:31:07 - 00:00:34:18
You’re going to grab your kit and you want to grab the water pouch.
00:00:34:20 - 00:00:37:02
From there, you're going to tear it open just like this.
00:00:37:02 - 00:00:38:19
But don't worry about how low the water is.
00:00:38:19 - 00:00:42:01
It's supposed to be like that. And not too much or too little,
00:00:42:01 - 00:00:44:11
because other than that, your results are trashed.
00:00:44:11 - 00:00:48:02
We're going to mix it up for 15 seconds, almost like you're making a mini cocktail.
00:00:48:06 - 00:00:48:12
00:00:48:12 - 00:00:50:05
Now you're going to take your testing strip
00:00:50:05 - 00:00:52:04
and you going to make sure that the arrows are right.
00:00:52:04 - 00:00:56:20
They're going to dip in up until the arrows for 15 seconds
00:00:56:20 - 00:00:59:22
and take your testing, strip out and lay it flat on the table
00:01:00:04 - 00:01:04:10
window side up and wait 3 minutes if there is one red line,
00:01:04:13 - 00:01:07:02
we don't want that Fentanyl detected in the mix.
00:01:07:02 - 00:01:09:18
Two red line. So no Fentanyl, you’re good to go!
Remove the test card from the sealed pouch and use it within 1 hour.
The reaction pad next to the GHB label should be a white to off white color. If it is any other color, do not use the test and open a new one.
Peel open the aluminum foil on the water tube.
Warning: Do not drink the liquid in the water tube.
Stir your drink 3-5 times, then use the dropper to extract a sample from the liquid of your drink and squeeze 2 drops from the dropper into the water tube.
Close the lid and shake it from side to side 5-8 times.
Place the test card on a clean and flat surface. Hold the water tube vertically and transfer 3 drops of diluted beverage into each sample well, as indicated.
Read the results after 5 minutes. Do not interpret the result after 10 minutes.
For GHB:
No Change in Color (Pad WillAppear Damp):NEGATIVE. Test does not detectGHB.
Any Change in Color (Pad Will Look Light Pink to Deep Purple in Hue): POSITIVE. Test detects GHB.
Pad Only Changes Color Halfway: INVALID. Dispose of test card and retest with a new one.
For Ketamine and Rohypnol:
3 Lines: NEGATIVE for both ROH & KET.Even a very faint line is negative.
1 Line at C: POSITIVE for both ROH & KET.
1 Line at C + 1 Line at ROH: POSITIVE for KET.
1 Line at C + 1 Line at KET: POSITIVE for ROH.
No Line or No Line at C: INVALID result. Dispose of test card and retest with a new one.